BFI-H2-32-0180-3F1X-TN

Article number 62157

  • Output power 4,0 kW
  • Output 3x230 VAC, 18 A
  • Input voltage 3x200-240 VAC
  • IP66
Contact Print (PDF)

Facts

General description

Article number 62157

Mechanical

IP class IP66
Physical size Size 3
Measurements (H x W x D) 310 mm x 211 mm x 273 mm
Weight 8.5 kg
Typical power loss at rated power 0,02
Main switch No
Built in Main switch, control switch and potentiometer No
Conformal coated PCBs No

Output ratings

Output voltage 3 x 230 VAC
Rated motor current 18 A
Overload capacity 110% for 60 seconds, 125% for 3 seconds
Motor power 4,0 kW
Output frequency 0 – 120Hz, 0.1Hz resolution
Supported motor types 3 phase AC induction (IM)
Built-in brake transistor No
Regenerative capacity No brake transistor

Input ratings

Supply voltage 200 – 240VAC ± 10%
Voltage fluctuations +/- 10%
Phase imbalance 3% maximum allowed
Displacement factor > 0.98
Supply frequency 48 – 62Hz
Power cycles 120 per hour maximum, evenly spaced
Total harmonic current distorsion No

Control specification

Control modes V/F Voltage Vector, Energy Optimised V/F
Current/torque limitation Current limitation
PWM frequency 4-32 kHz effective
Stopping mode Ramp to Stop: User Adjustable 0.1 – 600 seconds,Coast to Stop
Braking No
Skip frequency Yes
Analog setpoint control 0 to 10V, 10 to 0V, −10 to 10V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
Digital setpoint control 8 fixed speeds, Motorised Potentiometer, Internal PLC, Keypad, Modbus RTU, CANopen, Optional: PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCat, PROFINET, Modbus TCP, CC-Link

Communication

Modbus RTU 9.6 - 115.2 kbps selectable (8N1, 8N2, 8E1, 8O1)
BACnet MS/TP Built-in
Modbus TCP Yes, external option
Ethernet IP Yes, external option
EtherCat Yes, external option
Profinet IO Yes, external option
Profibus DP(DPV1) Yes, external option
Device Net Yes, external option
CC-Link Yes, external option
CAN open No

Display

Programmable display Yes
Multi language OLED display Yes
External OLED display Yes
LED display No

HVAC

PID-control Yes with sleep/wake up functionality
Spin start Yes
Pump dry protection Yes
Pump prime and burst protection Yes
Stir function Yes
Motor pre-heat Yes
Broken impeller and broken belt detection Yes
Automatic cleaning for pumps Yes
Bypass control Yes
Fire mode Yes

Control terminals

Power supply 100 mA @ 24 VDC, 20 mA @ 10 VDC
Inputs 5 in total, 3 Digital, 2 Analog or Digital, selectable
Digital inputs 10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply
Analog inputs Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling
Outputs 4 total, 2 relays, 2 analog or digital
Digital transistor outputs 24VDC/20 mA, Internal supply
Relay outputs Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC
Analog outputs 0 to 10 Volt, 0 to 20mA, 4 to 20mA
Safety inputs 2
Extra IOs Yes, internal option

Control features

Speed control Master/slave Yes, Master and slave
Modbus master functionality Yes, Master and slave
Advanced hoist control No
Built-in PLC Yes

Standard compliances

Low voltage directive Adjustable speed electrical power drive systems. EMC requirements
EMC directive 2004/108/EC, Cat C2 according to EN61800-3:2004
Conformance CE, UL
Machine directive 2006/42/EC
Marine approvals DNV-GL
Safe torque OFF Cat 3/PL"d" According to ISO 13849-1, SIL CL 2 According to EN61800-5-2 / EN62061 / IEC61508
Restriction of hazardous substances RoHS2
Registration evaluation and authorisation of chemicals Reach
Earth leakage current EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing
DC Bus discharge time EN 61800-5-1:2007
Electrostatic discharge EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009.
Dielectric strength 61800-5-1: 2007
Surge EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006.
Electrical fast transient burst EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004.

Ambient conditions

Temperature operation -10 to 40 °C
Humidity 95% max, non-condensing

Maintenance

Fault memory Last 4 Trips stored with time stamp
Data logging Logging of data prior to trip, Current, Temperature, DC Bus Voltage
Maintenence indicator Yes. Onboard service life monitoring
Monitoring Hours Run Meter, kWh/MWh meter

Resources

Limited availability

BFI-H2-32-0180-3F1X-TN

Article number 62157


EOL - End Of Life:
-

LTB - Last Time Buy:
-

LTD - Last Time Delivery:
-

LTR - Last Time Repair:
-

Replacement Parts: