X2 base 7 - F2 I/O00A
7'' HMI with iX runtime and IOs
- 800 × 480 pixel (16:9) TFT-LCD touch screen
- Built-in digital and analog IOs
- 200 MB application memory
- 1 × Ethernet, 4 × serial, 1 × USB as standard
- Operating temperature -10° to +50° C
- CE, FCC
Important life cycle dates, read more ->
Facts
General description
Part number | 630020105 |
Life cycle status | Mature |
Warranty | 2 year |
Certifications
General | CE, FCC |
Mechanical
Mechanical size | 196 x 146 x 84mm |
Mounting option | Panel Mount |
Number of touches | 1million finger touch operations |
Touch type | Resistive |
Cut-out size | 186 x 136mm |
Weight | 0,9 kg |
Housing material | Plastic (PC+ABS), Gray |
Buzzer | Yes |
LED | Yes |
Power
Input voltage | 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies. |
Power consumption (max) | 9.6W |
Input fuse | Internal DC fuse |
System
CPU | ARM9 400 MHz |
RAM | 128 MB |
FLASH | 256 MB, 200 MB free |
Display
Size diagonal | 7" diagonal |
Resolution | 800x480 pixels |
Backlight | LED Backlight |
Backlight life time | 20000 hours |
Backlight brightness | 400 cd/m2 |
Backlight dimming | Industrial Dimming |
Display type | TFT-LCD with LED backlight |
Digtal IO
Digital input | 8 inputs, 24 VDC at 5.6mA (0.13W per input) |
Cofiguration | 2 isolated, independent groups with 4 inputs per group. Each group shares one common contact. Supports sink/source mode for each group. |
Type | IEC 61132-2 Type I |
Isolation | 550 VAC, 1min |
Digital output | 6 outputs, 30 VDC, 3A max |
Configuration | 3 isolated, independent groups with 2 outputs per group. Each group shares one common contact. |
Type | Relays (contact configuration: SPST-NO) |
Isolation | 550 VAC, 1min |
Analog IO
Analog input channels | 4 |
Input type | 0-10V or 4-20mA |
Input impedance | According to EN 61131-2 |
Galvanic isolation | No |
Resolution | 14 Bit (0-10V: 0…16383 / 4-20mA: 3277…16383) |
Conversion time | 100ms per channel |
Accuracy | 0.3% |
Analog output channels | 2 |
Output type | 0-10V or 4-20mA |
Output impedance | According to EN 61131-2 |
Galvanic isolation | No |
Resolution | 14 Bit (0-10V: 0…16383/4-20mA: 3277…16383) |
Conversion time | 100ms |
Accuracy | 0.3% |
Serial communication
Number of serial ports | 2 Port 9pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS 232 |
Serial port 4 | RS 485 |
Ethernet communication
Number of Ethernet ports | 1 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Expansion interface
Expansion port | No |
SD card | No |
USB | 1xUSB 2.0 400mA |
Environmental
Operating temperature | -10°C to +50°C |
Storage temperature | -20° to +60°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP65 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Drivers
ABB - COMLI Master (5.7.2) |
ABB - COMLI Slave (4.11.0) |
ABB - TotalFlow (5.2.1) |
Allen Bradley - ControlLogix Ethernet IP (4.24.1) |
Allen Bradley - DF1 (5.8.0) |
Allen Bradley - DH485 (4.6.2) |
Allen Bradley - MicroLogix Ethernet (5.6.0) |
Allen Bradley - SLC5/PLC5 Ethernet (5.4.0) |
Altus - Alnet I (5.8.0) |
Animatics - SmartMotor (5.2.1) |
Beckhoff - ADS (5.12.1) |
Beckhoff - ADS Symbolic (4.7.0) |
Beijer Electronics - iX Demo (4.4.0) |
Bernecker + Rainer - Mininet (5.6.0) |
BoschRexroth - IndraDrive C (5.2.1) |
CAN - FreeCan (J1939/NMEA2000) (5.3.5) |
CAN - CANopen (5.4.0) |
CODESYS - ARTI v2.x, v3.x (4.8.0) |
CODESYS - SoftControl Direct Access (4.4.0) |
Cognex - InSight (5.2.2) |
Control Techniques - Unidrive (5.3.1) |
CTC - Serial Binary (5.4.2) |
Delta - PLC Modbus ASCII (5.6.0) |
Emerson - Modbus Master RTU/ASCII (5.4.0) |
Eurotherm - Easy Serial 631 (5.1.1) |
Fatek - Facon (5.10.0) |
Galil - DMC (5.2.2) |
GE Fanuc - Ethernet SRTP (5.5.0) |
GE Fanuc - SNPX (5.6.1) |
Gidding & Lewis - Motion control (5.4.0) |
IAI - Xsel (5.4.1) |
Idec - Computer Link (5.8.0) |
Johnson Control - JCONTROL (5.2.1) |
KEB - COMBIVERT (5.4.0) |
Keyence - KV-series (5.6.0) |
Koyo - DirectNET (5.5.0) |
Koyo - K Sequence (5.3.1) |
Lenze - LECOM A/B (5.6.0) |
LS Industrial System - Glofa (5.3.0) |
LS Industrial System - Master K (5.4.0) |
Matsushita - MEWTOCOL-COM (5.9.2) |
Mitsubishi Electric - Alpha2 (5.7.0) |
Mitsubishi Electric - A-series (C24) (5.6.0) |
Mitsubishi Electric - A-series (CPU) (5.10.0) |
Mitsubishi Electric - A-series (E71) (5.4.0) |
Mitsubishi Electric - Freqrol FR-A PLC (5.8.2) |
Mitsubishi Electric - FX Series ADP/BD (5.10.0) |
Mitsubishi Electric - FX Series ENET (5.4.1) |
Mitsubishi Electric - FX Series Serial (5.16.0) |
Mitsubishi Electric - MC Protocol (5.11.4) |
Mitsubishi Electric - MR-J2/MR-J3-T MELSERVO (5.9.0) |
Mitsubishi Electric - QnA/Qnn Serial (5.10.0) |
Mitsubishi Electric - QnA/Qnn (C24) (5.5.0) |
Mitsubishi Electric - Q-Series Ethernet (E71) (5.5.0) |
Modicon - Modbus Master (5.19.4) |
Modicon - Modbus Slave RTU/TCP (4.20.2) |
NEMA0183 - NEMA 0183 (4.6.0) |
Omron - Ethernet IP (4.3.3) |
Omron - FINS (5.9.5) |
Omron - Host Link (5.6.0) |
Regin - EXOline (5.3.2) |
Profibus - Profibus DP (5.5.1) |
SAIA - S-BUS Serial/Ethernet (5.7.0) |
Schneider Electric - Modbus (5.3.0) |
Schneider Electric - TSX Uni-Telway (4.5.3) |
Siemens - S5 PG/AS511 (5.4.0) |
Siemens - S7 200 PPI (5.8.5) |
Siemens - S7 over TCP (S7-200/300/400/1200/1500) (4.18.0) |
Siemens - MPI (HMI Adapter) (5.7.0) |
Siemens - MPI (CiX) (5.3.0) |
WAGO - Modbus TCP (5.10.0) |
Vigor - M/VB-Series (5.6.0) |
Yamaha - VIP (5.2.1) |
Yaskawa - Memobus Master (5.7.0) |
Yokogawa - FA-M3 (5.6.0) |
Resources
Drawings
- CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
- CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
- CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- CAB153 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
- CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
- CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
Product information
- Battery test summary - X2 base, C2 industrial PCs
- Environmental Report X2 base
- MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
- X2 export control and dual use
- X2 Letter of Volatility
Certificates
- UL E192000 for X2Base ,TxA, Exter
- X2 base KCC certification X2 base MSIP Certificate X2 base Permissive letter X2 base 5, X2 base 7, X2 base 10
- X2 base FCC Certification
- X2 base DoC CE ROHS
- X2 base CE certification
- DoC ECCN for X2 series HMI
- SDoC Green Passport
- RoHS and REACH Declaration of Conformity
- Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
Knowledge
- IX otf and ttf fonts
- iX Developer SP7 - 2.47.473 Release information
- Driver MODICON Modbus Slave: Command XDNCW
- Windows CE versions, X2, iX, E1000
- Creating a custom Welcome Screen \ startup screen on a X2 pro operator panel
- iX - SMTP - Using Gmail servers using App password
- How to download Free software packages from SmartStore
- OPC ua settings in Phoenix plxnext engineer
- Image Sticking
- Best Practice Database on SD card or flash memory
- Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
- Max number of recipe items / tags
- Convert from Exter/E1000 To X2 Series
- X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32
Information document
Software
- SqlProxy - Connects iX Panels transparently to SQL Server
- Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
Brochures
System program
EOL information
- 17--TtL_beijer_electronics_life_cycle_notification--X2-base_image_ADP
- 16--TtM_beijer_electronics_life_cycle_notification--X2 base and X2 base ADP
Program examples/Start-up
- Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
- Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406
- Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
- Copy Debug log to accessible folder
- X2 Date time picker script
- IX alarm info request lookup in pdf by page index
- Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
- Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
- iX Templates for E-key and X-Key
- Add Tags to Tagmonitor by script
- Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
- Ping from IX x2 terminal
- iX Developer - Top10 Alarm list, based on count and/or duration
Manuals
Drivers
Configuration files
Limited availability
X2 base 7 - F2 I/O00A
7'' HMI with iX runtime and IOs
EOL - End Of Life:
-
LTB - Last Time Buy:
12/31/2023
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: