ST-3428
8 analog inputs module
- Input voltage 0-10 VDC
- Input resolution 12 bits
Important life cycle dates, read more ->
Facts
General description
Article number | 311396 |
Article status | EOL |
Warranty | 1 year |
Mechanical
Mechanical size | 12 mm x 99 mm x 70 mm |
Module weight | 70 g |
System indicators | 1 green/red Fn-Bus state |
Input specification
Input type | Analog input 0~10 VDC |
Number of inputs | 8 channel single ended |
Data format | 16 bit integer |
Resources
Drawings
- AutoCAD drawing including block for Crevis FnIO-S Series
- Autocad (dwg) drawings connection diagram for FnIO S-Series
- Application Note Crevis I/O - Important electrical info for Crevis I/O. How to build a stable and safe system
- Autocad drawings (pdf) connection diagram for Crevis FnIO-S Series
- FnIO S Series, Cable connection (ST-RTB Wiring Specification)
Knowledge
- Crevis ST-3708 - Divergent (bad) values QA: Check if 3-wire sensor is used and NOT 2-wire)
- CoDeSys, PIO (NA-9379), ST-3702 change Pt100 to Pt1000
- ST-3704, ST-3708, Wrong value in catalog, manuals and IO Guide Pro
- FnIO, Analog IO update Time
- ST-3704, ST-3708, Analog temperature (RTD) modules
- ST-3702, ST-3704, ST-3708, Overall accuracy
- ST-3702, ST-3704, ST-3708: Ni1000-LG
- ST-3702, ST-3704, ST-3708, Filter Type (parameter)
- ST-3702, Data Resolution not supported
- ST-2792 and ST-4491, Modules for Building Automation industry
- Output with diagnostic, Crevis
- Max lamp load in FnIO, example ST-2328
- CODESYS do not support read/Write to Memory Register Map at Crevis S-series
- High-speed Counter modules ST-5101, ST-5111, ST-5112, ST-5114, A/B phase
- ST-5101 (ST-5111), Latch function
- ST-5111, How does the module work at overflow
- NA-9286, Fault Action Setting (Output)
- NA-9286, Check if communication is OK?
- NA-9289, IP setting Method, BootP and DHCP
- IP setting on NA-9289
- NA-9131, Input / Output area
- NA-9131, CC-link, Change and calculation of occupied stations
- NA-9188, IP-setting
- Online change with Update boot application will delay scantime
- Beijer Electronics - Device Runtime and Compiler versions in CODESYS
- FnIO-S Series (Crevis), Supported Modbus Functions Codes
- PIO Index was outside the bounds of the array
- PIO - OPC connection
- Start-up document: Setup NA-9373 (PIO) as Modbus RTU master
- NA-9161, Max Analog Input and Analog Output
- NA-9131, Clear outputs when network error
- NA-9286, NA-9289, Change parameter in I/O moduls with IO Guide Pro
- NA-9189, IP-Adress setting with ARP and IO Guide Pro
- NA-9189, Modbus TCP node default IP adress
- NA-9173, NA-9171, Max Watchdog time
- NA-9189, Modbus TCP node default IP adress
- NA-9173, initial settings of node
- NA-9189, How to change the TCP Connection Timeout parameter
- NA-9173, Maximum number of device without repeater (Modbus RS485)
- NA-9473, The output are not RESET when there are communications error
- TxB Softcontrol - Check communication status against ModbusTCP (NA-9289)
- NA-9122, Extended Diagnostic information
- NA-9122, Configuration
- FnIO Bus Time, NA-9122
- Common noise filter NBH-06-432-D to FnIO S- and M-series (for DNV certificate)
- FnIO M-, G- and S-series Serial number and Production date
- How to download Free software packages from SmartStore
Cable guide
Firmware
Manuals
Certificates
- Type Approval: LR Approval FnIO S-series
- DNV Approval FnIO S-series
- CE Declaration of Confirmity, Crevis FnIO S-Series and AT2-Series
- Type Approval: UL certificate FnIO
Catalogues
Program examples/Start-up
- CoDeSys in TxA SoftControl, ST-3702 change Pt100 to Pt1000
- Program example, Parameter Set of Crevis special modules, S-series (Modbus RTU), CODESYS
- BCS Tools/Nexto - Modbus TCP and Crevis I/O, init ST-3702
- NA-9286, Change parameter for I/O module (Codesys)
- Program example for Crevis ProfibusDP, ST-5212 and QJ71PB92V
- iX TxB-SC, Parameter Set in ST-5111 (EtherCAT NA-9286)
- iX TxB-SC, NA-9289, ST-5101, ST-5111, ST-5112, ST-5114, Program example
- iX TxB-SC, NA-9286, ST-5101, ST-5111, ST-5112, ST-5114, Program example
- Program example CODESYS, Modbus TCP Master (TxB-SC ) and Memory Register Map in ST-5111
- PIO (NA-9372), ST-5101, ST-5111, ST-5112, ST-5114, Program example
- Start-up: iX TxA SoftControl, FnIO-S NA-9173 / NA-9473 Modbus RTU (KI00327)
- Start-up: iX TxB SoftControl, NA-9286 EtherCAT (KI00329) (Codesys runtime 3.5.1.40)
- Start-up: iX TxB SoftControl, NA-9173/NA-9473 Modbus RTU (KI00331) (Codesys runtime 3.5.1.40)
- Program example, NA-9373 (PIO) controls NA-9173 (serial modbus node) via Modbus RTU
- Program example, Modbus TCP Master to PIO (NA-9372) Modbus TCP Slave
- NA-9372 Program example, Real Time Clock (RTC)
- Start-up: Crevis FnIO-S Series, IP address, Subnet and Gateway Setting (KI00380)
- NA-9379 Program example, Real Time Clock (RTC)
- NA-9372, NA-9373, Modbus Slave (TCP or RTU) function
- Start-up document for IOGuidepro and NA-9173
- Program example for Crevis ProfibusDP and Siemens S7 315-2 DP
Data sheets
- Crevis FnIO-S: Datasheet Analog Input module
- ST-3802
- ST-3714
- ST-3804
- ST-3708
- ST-3428
- ST-3424
- ST-3xxx, Parameter and Mapping
- ST-3808
- ST-3234
- ST-3444
- ST-3218
- ST-3214
- ST-3134
- ST-3118
- ST-3114
- ST-3524
- ST-3544
- ST-3704
- ST-3702
- ST-3644
- ST-3624
- Crevis FnIO-S: Datasheet Analog Output module
- ST-4274
- ST-4422
- ST-4622
- ST-4522
- ST-4491
- ST-4474
- ST-4424
- ST-4xxx, Parameter and Mapping
- ST-4212
- ST-4114
- ST-4112
- ST-4214
- Crevis FnIO-S: Datasheet Communication module
- ST-5211
- ST-5212
- ST-5232
- ST-5231
- ST-5221
- ST-5xxx, Parameter and Mapping
- Crevis FnIO-S: Datasheet Digital Input module
- ST-122F
- ST-1228
- ST-1224
- ST-121F
- ST-1218
- ST-1214
- ST-112F
- ST-1124
- ST-1114
- ST-1xxx_Parameter
- ST-1904
- ST-1804
- ST-132F
- ST-1324
- ST-131F
- ST-1314
- ST-2748
- ST-2792
- ST-2852
- Crevis FnIO-S: Datasheet Digital Output module
- ST-2328
- ST-2114
- ST-221F
- ST-2744
- ST-2744
- ST-2742
- ST-2624
- ST-2614
- ST-2524
- ST-2124
- ST-2514
- ST-2414
- ST-2324
- ST-2318
- ST-2314
- ST-222F
- ST-2424
- ST-2xxx, Parameter and Mapping
- Crevis FnIO-S: Datasheet Highspeed Counter module
- ST-5114
- ST-5112
- ST-5101/ST5111
- Data Sheet ST-5651, PWM 1 channel Output RS485
- Data Sheet ST-5641 and ST-5642, Pulse
- NA-9189, MODBUS TCP Network Adapter
- NA-9286, EtherCAT Network Adapter
- Crevis FnIO-S-Series: Environment
- NA-9111, NA-9112 Device Net Network Adapter
- NA-9122, Profibus DP Network Adapter
- NA-9161, CANopen Network Adapter
- NA-9131, CC-Link Network Adapter
- NA-9171, Modbus RS232 Network Adapter
- NA-9188, Ethernet/IP Network Adapter
- NA-9187, PROFINET I/O RT Protocol Network Adapter
- NA-9173, Modbus RS485 Network Adapter
- NA-9289, MODBUS TCP Network Adapter
- Crevis FnIO-S: Datasheet Power Supply module
- Data Sheet ST-7008 and ST-7408, Shield
- Data Sheet ST-7108 and ST-7508, Common
- Data Sheet ST-7241 and ST-7641, Field distributor
- Data Sheet ST-7588, Common
- Data Sheet ST-7111 and ST-7511, ExpansionPower
- Data Sheet ST-7188, Common
- Data Sheet ST-7118 and ST-7518
- NA-9372, Programmable I/O
- NA-9373, Programmable I/O
- Data Sheet ST-5444, 4Channels PWM Output
- Data Sheet ST-5442, 2 Channels PWM Output
- Data Sheet ST-5422 and ST-5442
- Data sheet ST-5351, SSI Interface 1 channel
- NA-9261, CANopen Network Adapter
- NA-9222, Profibus DP Network Adapter
- NA-9288, Ethernet/IP Network Adapter
Configuration files
- NA-9222, GSD-file for ProfibusDP
- NA-9286, XML-files for Crevis EtherCAT node
- NA-9372, NA-9373 (PIO) Device Description
- NA-9261, EDS-file for Crevis CANopen
- EDS-file for Crevis DeviceNet node NA-9112
- EDS-file for Crevis Ethernet/IP node NA-9188
- NA-9288, EDS file Ethernet/IP
- NA-9187 Profinet, GSDML-file
- GSD-file for Crevis Profibus node NA-9122
Software
- IOGuidePro
- CODESYS 3.5 SP3 Patch 1 (required for Crevis S-series PIO)
- IO Guide Pro Ver 1_2_0_3 for S- and G-series
System program
Product information
Limited availability
ST-3428
8 analog inputs module
EOL - End Of Life:
6/23/2022
LTB - Last Time Buy:
6/23/2022
LTD - Last Time Delivery:
6/23/2022
LTR - Last Time Repair:
6/23/2022
Replacement Parts:
See product information: Conversion guide for alternative products between S-series remote IO to G- or M-series