GL-9972
Programmable I/O with CODESYS
- 16 MB program memory
- CODESYS RT 3.5 SP17 P3
- 1xRJ45 Ethernet 10/100 Mbps + 1xRJ45 serial port
- 16 MB Data / 32 kB Non-volatile memory (Retain: 16 kB)
- Modbus RTU / TCP, ARTI, OPC UA
- Filesystem, online change and breakpoints
- Up to 63 expansion slices
Facts
General description
Article number | 100-8104 |
Warranty | Up to 2 years |
Article status | Active |
Shock operating | IEC 60068-2-27 (15G) |
Vibration resistence | Sine vibration (based on IEC 60068-2-6), 5 ~ 25 Hz: ±1.6mm, 25 ~ 300 Hz: 4G, Sweep rate: 1 octave/min., 20 cycles, Random vibration (based on IEC 60068-2-64), 10 ~ 40 Hz: 0.0125g²/Hz, 40 ~ 100 Hz: 0.0125 → 0.002g²/Hz, 100 ~ 500 Hz: 0.002 g²/Hz, 500 ~ 2000 Hz: 0.002 → 1.3 x 10-4g²/Hz, Test time: 1hrs for each test |
Industrial emissions | EN 61000-6-4: 2019 |
Industrial immunity | EN 61000-6-2: 2019 |
Installation position | Horisontal, Vertical |
Product certifications | CE, UL, cUL, FCC, RoHS, China RoHS, Reach |
System power | Nominal supply voltage: 24 VDC, Voltage range: 60℃: 18~32 VDC, 70℃: 18~26.4 VDC, Output current limitation: 1.5 A, Reverse polarity protection |
Power dissipation | Max. 50 mA @ 24 VDC |
Current for IO module | 1.0 A @ 5 VDC |
Isolation | System power to internal logic: Non-Isolation , System power I/O driver: Isolation |
Field power | Nominal supply voltage: 24 VDC, Voltage range: 60℃: 18~32 VDC, 70℃: 18~26.4 VDC, * Field Power Range is different depending on IO Module series. Refer to IO Module`s Specification. |
Max current field power contact | DC 8 A max |
Weight | 84 g |
Module size | 22x109x70mm |
Communication
Station type | Master & Slave node (Modbus TCP, Modbus RTU) |
Max expansion ports | 63 slices |
IO data size | Max. data size (Input + Output): Max 128 Byte each slot |
Max length bus line | 100 m |
Max network nodes | 64 MODBUS/TCP master or slave nodes can be connected (ie. Max. socket TCP: 64, UDP: 16) |
Baud rate | MODBUS RTU baud rate: 2400 - 115200 bps |
Bus connection | 2 x RJ45 (1xRJ45 Ethernet & 1xRJ45 Serial) |
Indicator | 6 LEDs, 1 green / red, module status (MOD), 1 green / red, network status (NET), 1 green / red, PLC Run/Stop status (RUN), 1 green / red, expansion I/O module status (IOS), 1 green, system power status, 1 green, field power Status |
Module location | Starter module left side |
Field power detection | ~14VDC |
Environmental
Mounting | 35mm DIN rail |
Operating temperature | -20 ~ 60℃ |
Storage temperature | -40 ~ 85℃ |
UL temperature | -20 ~ 60℃ |
Relative humidity | 5 ~ 90% non-condensing |
Resources
Configuration files
File name | Date | |
---|---|---|
G-Series Programmable IO - Device Description (XML) | 2024-07-07 07:30:48 | |
GT-5904 - Device Description XML (Beijer) | 2025-03-12 08:16:13 |
Software
File name | Date | |
---|---|---|
G series, BootP Server for IP-setting at GN-9372 and GN-9289 | 2022-09-20 15:49:06 | |
PIO Firmware Update Tool, for G- and M-series devices | 2025-01-03 10:52:42 | |
CODESYS V3.5 SP11 Patch 3, required for G- and M-series PIOs FW rev 2.xxx | 2023-03-15 14:55:35 | |
IO Guide Pro 1.2.0.3, for S- and G-series | 2024-09-24 08:05:44 | |
IOGuide2(Beijer)_BETA_20250220 G- and M-series devices | 2025-03-12 07:40:11 | |
IO Guide Pro 1.4.0.0 beta2, for Beijer G-series | 2024-09-24 08:02:50 |
Firmware
File name | Date | |
---|---|---|
Release Notes for PIO - Programmable IO | 2024-10-28 12:44:09 | |
G series, GL-9972 PIO - Update firmware | 2023-12-18 13:36:25 |
Knowledge
File name | Date | |
---|---|---|
Online change with Update boot application will delay scantime | 2023-08-10 20:58:10 | |
CNT-8412 (5-pin) powerplug / connector to GL-9xxx network adapters and PIO | 2025-01-09 13:40:42 | |
CODESYS Trace feature for PIO modules | 2024-08-09 08:51:11 | |
Ethernet port specification of G- / M-series PIO and Network adapters | 2024-05-03 07:55:52 | |
BCS Tools - SFC errors at compile | 2024-02-07 08:21:44 | |
Not possible to add features to the CODESYS license of standard PIO | 2025-01-03 11:31:07 | |
Programmable IO - Release Notes / Revision history | 2024-04-19 10:14:26 | |
Change of retain area size Programmable IO | 2025-01-08 08:21:21 | |
FnIO M-, G- and S-series Serial number and Production date | 2023-07-20 11:30:16 | |
Shock resistance of G- and M-series (IEC 60068-2-27) | 2022-09-06 14:16:00 | |
How to download Free software packages from SmartStore | 2025-05-08 10:17:08 |
Program examples/Start-up
Manuals
Drawings
File name | Date | |
---|---|---|
Remote IO serial Modbus RS485 wiring (RTU) | 2023-04-04 16:18:48 | |
G- and GL-series Drawing, 3D / 2D CAD files (Mechanical) | 2025-04-30 09:21:46 | |
G- and GL-series Drawing, 2D CAD files #1 (Electrical) | 2025-05-09 11:16:19 |
Product information
File name | Date | |
---|---|---|
Conversion guide for alternative products between S-series remote IO to G- or M-series | 2022-09-06 11:38:29 |
Brochures
File name | Date | |
---|---|---|
G series brochure, BREN636 (english) | 2022-09-26 08:38:34 |
Certificates
File name | Date | |
---|---|---|
UL & cUL Certificate of compliance - Beijer G-series | 2023-05-26 08:32:02 | |
CE DoC (Declaration of Conformity) for Beijer G-series modules following the EMC & LV directive. | 2025-01-22 13:07:12 |
Smart Engineering Resources
Limited availability
GL-9972
Programmable I/O with CODESYS
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: